Electrical installation

Motor connection

4

l

58

EDKLCMW3024−SPS DE/EN 7.0

4.4

Motor connection

lcu121_000d

X21 − Motor 1 connection

Pin

Connection

Description

Data

Connector: Socket, Harting HAN−Modular

a1

U1

Phase U1

Output voltage = mains voltage
Max. continuous output current
dependent on type
(sum of all output currents)

a2

V1

Phase V1

a3

W1

Phase W1

c1

+PTC

Motor temperature monitoring

PTC thermistor (PTC) or thermal contact
(NC contact)

c2

~

Brake rectifier supply voltage

The brake rectifier is installed in the motor
terminal box

c3

~

c4

S1

Switch for disconnection on the DC side

c5

S2

c6

−PTC

Motor temperature monitoring

PTC thermistor (PTC) or thermal contact
(NC contact)

+

PE

PE conductor