Electrical installation, Safety engineering – Lenze ELCAMWIxxx4SNNPSNN (LCU 121) Benutzerhandbuch

Seite 61

Advertising
background image

Electrical installation

Safety engineering

4

l

61

EDKLCMW3024−SPS DE/EN 7.0

lcu12x_000e

X60 − Safe inputs, safe outputs

Pin

Signal

Description

Data

Connector: Socket, 26−pin, M27, N−coded

1

O1A

Output 1 channel A

2

O1B

Output 1 channel B

3

GO

Reference potential for O1A and O1B

4

O2A

Output 2 channel A

5

O2B

Output 2 channel B

6

GO

Reference potential for O2A and O2B

7

CLB

Clock output, channel B

only for passive sensors

8

CLA

Clock output, channel A

9

GCL

Reference potential for CLA and CLB

10

I1A

Sensor input 1, channel A

only for equivalently switching passive
sensors

11

I1B

Sensor input 1, channel B

12

GI1

Reference potential for I1A and I1B

13

I2A

Sensor input 2, channel A

only for equivalently switching passive
sensors

14

I2B

Sensor input 2, channel B

15

GI2

Reference potential for I2A and I2B

16

I3A

Sensor input 3, channel A

only for active sensors

17

I3B

Sensor input 3, channel B

18

GI3

Reference potential for I3A and I3B

19

I4A

Sensor input 4, channel A

only for active sensors

20

I4B

Sensor input 4, channel B

21

GI4

Reference potential for I4A and I4B

22

n. c.

Not assigned

23

n. c.

Not assigned

24

n. c.

Not assigned

25

n. c.

Not assigned

26

n. c.

Not assigned

Advertising