2 rated data, Rated data, Technical data – Lenze ELCAFHIxxx4E34NNER Highline Benutzerhandbuch

Seite 57: 2 rated data input data

Advertising
background image

Technical data

Rated data

2

l

57

EDKLCFH3024−EER DE/EN 2.0

2.2

Rated data

Input data

Basis of the data

Mains

Voltage

U

LN

[V]

Voltage range

U

LN

[V]

Frequency range

f [Hz]

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 − 0 % ... 65 + 0 %

Cyclic mains switching

Type

ELCAFHI7514

Max. 5 switchings / 5 minutes

ELCAFHI1524

ELCAFHI3024

Voltage

Frequency

Current (T

a1

)

1)

Current (T

a2

)

2)

Number

of phases

Typ

[V]

[Hz]

[A]

[A]

ELCAFHI7514

400/500

50/60

3.3/2.6

2.1/1.6

3

ELCAFHI1524

400/500

50/60

5.5/4.4

3.4/2.8

3

ELCAFHI3024

400/500

50/60

9.0/7.9

5.6/4.9

3

1)

Ta1 = max. 40 °C ambient temperature during operation

2)

Ta2 = max. 55 °C ambient temperature during operation

Supply voltage for control electronics of the controller
(safely separated power supply unit SELV/PELV)

Typ

Voltage range U

DC

[V DC]

Current consumption at + 24 V DC [A]

Min.

1)

Max.

2)

ELCAFHI7514

+ 24

(+19.2 − 0 % ... +28.8 + 0 %)

1.9

4.4

ELCAFHI1524

ELCAFHI3024

1)

No digital inputs and outputs connected

2)

All digital inputs and outputs connected