`зггмебЕ~нбзе й~к~гЙнЙкл зС нЬЙ вЙуй~З
In the sample project

H310_93xx.vts the CAN adapter of the controller is the component “93xx” (slave).

This automatically declares the keypad as master.

Mark the component CAN port in the project area and select

Edit

Parameters to open the

Port Parameters dialog box:

Keypad declared as master

Keypad declared as slave

Enter the baud rate for the controller in the Communication Parameters field.
Ó The baud rates for the 9300 Servo inverter and the 9300 Servo PLC are saved under code

C0351 (CAN bus baud rate).

After the keypad has been declared as slave:
Ó Enter a terminal address in the Terminal’s properties field. This address must not be identical

with the device address (CAN bus node address C0350 of the controller).

( 40)

Ó The settings under Sync time and Cycle time remain unchanged.

After the keypad has been declared as master:
Ó The Terminal’s properties field remains unchanged.

Confirm with

OK.

qáé>

The value set under Baud rate must be identical with the setting in the controller.

If the keypad has been declared as slave, the ”Terminal address” in the Terminal’s properties