Hmi designer – Lenze HMI Designer Getting Started Benutzerhandbuch

Seite 48

Advertising
background image

HMI Designer

L

QU

EDBHMI-DEEN DE/EN 4.0

`зенкзд нЬЙ ЕзенкзддЙк

shift

F1

Esc

F2

F3

F4

F5

Help

Info

F1 => PARAMETER

F2 => CONTROL INVERTER

Controller enable (RFG), quick stop (QSP), Nset,

Nact

Press

<shift> + <F2>.

shift

F1

Esc

F2

F3

F4

F5

Help

Info

F1=>RFG:ON

F2=>QSP:OFF

Controller enable (RFG)
1. Press

<Left arrow> or <Right arrow> to go to

line “F1=>RFG:”.

2. Press

<shift> + <F1> to inhibit or enable the

controller.

– “F1=>RFG: ON”: Controller is enabled
– “F1=>RFG: OFF”: Controller is inhibited

Note!
To enable the controller, a HIGH signal must be

applied at terminal X5/28.

Quick stop (QSP)
1. Press

<Left arrow> or <Right arrow> to go to

line “F2=>QSP:”.

2. Press

<shift> + <F2> to set or reset quick

stop.

– “F2=>QSP: ON”: Quick stop is set
– “F2=>QSP: OFF”: Quick stop is reset

shift

F1

Esc

F2

F3

F4

F5

Help

Info

N-SET :100.00%

N-ACT :3000rpm

<F3

Nset, Nact
1. Press

<Down arrow> to go to the next page.

2. Press

<Select parameter> to enter a value for

Nset.

3. Enter the desired value using

<Up arrow> and

<Down arrow>.

4. Confirm with

<Confirm input>.

5. Press

<shift> + <F3> to return to the first page

(start page).

Note!

A HIGH signal must be applied at terminal

X5/E3 for the input of the setpoint.

“Nact” displays the actual speed of the

controller. You cannot change this value.