Programming plan, Output time p1 42, Output time p2 – Baumer NE134 Benutzerhandbuch

Seite 14: Code setting 51, Baudrate 52, Parity 53, Stop bits 54, Address, Separating line, Ne134

Advertising
background image

NE134

14 www.baumer.com

41

0.2 5

4 1

Output time P1

42

0.2 5

4 2

Output time P2

50

0 0 0 0

5 0

Code

setting

51

0

5 1

Baudrate

52

0

5 2

Parity

53

0

5 3

Stop

bits

54

0 0

5 4

Address

55

- - - - - -

Separating line


9. Programming Plan

Lines 11-17 Status of lines 1-7

0

Parameter alteration accessed

1

Clear resp. input lock

2

Skip parameter

Line 21

Operation Modes Main counter

0 *

Add. – Reset to SC, Stop contact P2

1

Sub. - Autoreset at SC, Stop contact at SC

2

Sub. - Autoreset at 0, Stop contact at SC

Line 22

Preset Mode

0 *

Main counter 2 presets (step presets)

1

Main counter 2 Presets (P1 = trailing
preset)

2

Main counter with preset P2, batch with P1

Line 23

Kinds of Reset

0 *

Main counter and batch counter with
autoreset

1

Main counter w/o,batch counter with
autoreset

2

Main counter with,batch counter w/o
autoreset

3

Main counter and batch counter w/o autoreset

Line 24

Decimal Point for PC, (P1,) P2, SC and tot

0 *

No decimal point

1

00000.0

2

0000.00

3

000.000

Line 26

Measuring unit displayed

0 *

No measuring unit

1

m

2

dm

3

cm

4

mm

5

L

Line 27

Lower Dispaly Assignment

0

W/o lower display

1

P1 - Preset value

2 *

P2 - Preset value

3

SC - start count

4

tot – totalizer

5

b - batch counter

6

SF - scaling factor

Line 30

Counting Mode

0 *

Count track A / direction inversion track B

1

Difference (A-B)

2

Total (A+B)

3

Track A 90° B single evaluation

4

Track A 90° B double evaluation

5

Track A 90° B fourfold evaluation

Line 31

Frequency Main counter track A

0 *

10 kHz

1

25 Hz

2

3 Hz

Line 32

Frequency Main counter track B

0 *

10 kHz

1

25 Hz

2

3 Hz

Advertising