Baumer NE215 Benutzerhandbuch

Seite 20

Advertising
background image

NE215

20 www.baumer.com

Line 38

Time basis for tachometer
function

0 1 second
1 2 Seconds
2 3 Seconds
3 6 Seconds
4 10 Seconds
5 20 Seconds
6 30 Seconds
7 60 Seconds

Line 39

Not applicable

Line 40

Function Operating time meter

0 Operating time meter is running
1 Operating time ON / OFF

Line 41

Code setting

0000 Code not active
:
9999

Line 43

Baud rate

0 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud

Line 44

Parity

0 Even Parity
1 Odd Parity
2 No Parity

Line 45

Device address

00 Minimum value
:
99 Maximum value

Line 46

Stop Bit

0 1 Stop Bit
1 2 Stop Bit

Advertising