9. Programming plan

Line 11-17 Status line 1-7

0 *

Enable parameter alteration

1

Clear resp. parameter lock

2

Skip parameter

Line 24

Decimal point F, P1, P2

0 *

No decimal point

1

0000.0

2

000.00

3

00.000

Line 26

Measuring unit

0 *

No measuring unit

1

1/h

2

1/min

3

1/s

Line 27

Standard display lower line

0

No lower display line

1

P1 – preset (limit)

2 *

P2 – Preset (limit)

3

bF – Evaluation tacho F

4

b - batch counter

5

SF – scaling factor batch counter

Line 28

Update time (display repetition)

0

0,5s

1 *

1 s

2

2 s

3

3 s

4

5 s

5

10 s

6

20 s

7

30 s

8

60 s

Line 29

Timeout signal input B (terminal 8)

0 *

1 s

1

2 s

2

3 s

3

5 s

4

10 s

5

20 s

6

30 s

7

60 s

8

Timeout OFF

9

Timeout OFF, save recent value displayed
in
case of power failure

Line 30

Unit time tachometer

0 *

1/min

1

1/s

2

1/h

Line 31

Frequency track B tacho

0 *

40 kHz

1

25 Hz

Line 32

Frequency track A batch counter

0 *

10 kHz

1

25 Hz

2

3 Hz

Line 33

Input logic signal inputs A,B

0 *

PNP trigger threshold 6 V

1

NPN trigger threshold 6 V

2

PNP trigger threshold 3 V

3

NPN trigger threshold 3 V

Line 34

Function control input 1 (terminal 9)

0 *

Hold for tacho and batch counter

1

Programming lock

2

Keylock

3

Print

Line 35

Response time control input 1

0 *

30 ms

1

100 µs

Line 36

Function control input 2 (terminal 10)

0

Hold for tacho and batch counter

1 *

Programming lock

2

Keylock

3

Print

Line 37

Function control input 3 (terminal 11)

0 * Batch counter – static reset
1

Batch counter – edge-triggered reset

2

Programming lock

3

Keylock

4

Print

Line 40

Output logic digital outputs

0 * Both outputs normally closed
1

P1 normally open, P2 normally closed

2

P1 normally closed, P2 normally open

3

Both outputs normally open

Line 47

Assignemnt limit P1

0 * Max. limit
1

Min. limit

Line 48

Assignment limit P2

0 * Max. limit
1

Min. limit

Line 49

Output response MIN.limit

0 * With starting lock (triggered only when

dropping below)

1

no starting lock

Line 50

Code

0000 * Code not active
:

9999

Line 51

Baudrate

0 * 4800 Baud
1

2400 Baud

2

1200 Baud

3

600 Baud

Line 52

Parity

0 * Even Parity
1

Odd Parity

2

No Parity

Line 53

Stop bits

0 * 1 Stop bit
1

2 Stop bits

Line 54

Identifier

00 * Default
00

Min.

99

Max.

Advertising