Psen op67-69k operating instructions – Pilz PSEN op67-69K-135/1 Benutzerhandbuch

Seite 16

Advertising
background image

EN

1002401-2EN-01

PSEN op67-69K

Operating instructions

4

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

Original document

Fig. 2

Fig. 3

Then insert the spacers into the lateral grooves of the PILZ safety

light curtain as far as the end (Fig. 4) and tighten the screws to

attach the light curtain to c. Repeat the same step for part b; make

sure that the safety light curtain cable (which must be connected

before starting the light curtain assembly) is guided through the

relevant hole of the M16 cable conduit before tightening the screws

(Fig. 5).

Fig. 4

Fig. 5

When both parts b and c are fully installed on the light curtain,

tighten the nut to secure the cable. Check again that the M5x6 UNI

TE 5739 screws are firmly seated.

If the system looks like the illustration in Fig. 6, it can be placed

inside the transparent tube (Fig. 7).

M5 square nut

M16 cable conduit with ring nut,

untightened

Elastic

washer

TE M5x6 UNI 5739 screw