Power-ON Utilities


There are three power-ON utilities to set up and test printer hardware. These
utilities are activated by pressing the FEED button then turning on the printer
power simultaneously and release the button at different LED light indications.

Power-ON Utility options

Follow the steps below for different power-on utilities.

1.

Turn OFF the printer power button.

2.

Press down the FEED button then turn ON the power button .

3.

Release the power button when the LED color turns to amber,
continue pressing the FEED button .

4.

Release the FEED button when the green LED indicates the desired
function:










Media sensor calibration

Follow the steps below to calibrate the media sensor.

1.

Turn off the printer power.

2.

Hold on the FEED button then turn on the power button

3.

Release the power button when the LED color turns
amber, continue pressing the FEED button.

4.

Release the FEED button when the LED indicates
and blinking. The LED will sequence right to left, 5 blinks each.

5.

The printer will calibrate the sensor sensitivity.


Power on utilities

The following LED light pattern will determine the function:

LED

Functions

(Solid)

(5 blinks)

(5 blinks)

(5 blinks)

(Solid green)

1. Media sensor calibration

Release

2. Self-test and enter dump

mode

Release

3. Printer initialization

Release