4. QUESTIONS & ANSWERS/TROUBLESHOOTING

The air coupling will not lock in position when connecting to the bus.

Answer: The starter inhibitor sensor has been fitted too far out, see the bus plate installation

instructions.

Answer: The spacer on the air nipple is missing or has been incorrectly fitted. The air nipple

on the bus plate must be fitted with a 7 mm spacer on the front (older versions may

have two spacers, one 5 mm and the other 2 mm). Check that the spacer(s) is/are

correctly fitted.

The starter inhibitor is not working.

Answer: The electrical cables have become disconnected.
Answer: The starter inhibitor sensor has been fitted too far in, see the bus plate installation

instructions.

The hose plate does not fit on the bus/ramp plate.

Answer: The plate is bent, making the opening too small. Straighten the plate or replace the

U profile where necessary.

Connection of the plates feels stiff.

Answer: The fluid coupling should be regularly lubricated; see the separate maintenance

and servicing instructions.