6.4 Verifying electronic devices

In accordance with the applicable German safety regulations (Accident Prevention and
Insurance, BGV A2/A3), electrical installation and equipment have to undergo inspection
at regular intervals. For this purpose, the fixing screw of the 5-pin DMX socket may serve
as measuring point for the insulation and fault current measurement. This screw is
connected to all sheet metal parts by means of a contact disc.

PE-measuring point

6.3 Software update

To update the fixture via PC/Notebook, a Upgrade-Dongle (USB/DMX converter) with
software is required. The upgrade-dongle has to be connected to the fixture with a 5 pin
XLR connector. The software for the products is available from the JB-Lighting homepage
at www.jb-lighting.de