7 info – JB-Lighting Sparx 10 Benutzerhandbuch

Seite 41

Advertising
background image

- 41 -

10

Operation in Master-Slave mode:
To set a fixture to slave-mode navigate to REMOTE. To activate the slave function press “ENTER”
(keep it down) and press “ESC” in addition. The display will show either REMOTE INACTIVE if no
DMX-signal is being received or REMOTE ACTIVE if a DMX-signal is being received. To leave this
function press “ESC” (keep it down) and press “ENTER” in addition. Connect the Sparx10 with
DMX cables. Select STANDALONE -> RUN with the master fixture. Start function by pressing
“ENTER” (keep it down) and pressing “ESC” in addition. All connected fixtures will repeat the
steps synchronized to the master fixture. To leave the menu press “ESC” (keep it down) and press
“ENTER” in addition. If you realize that a fixture reacts inaccurate check if the display shows
REMOTE ACTIVE.

4.7 INFO

The menu informs about the current software/firmware version. The non-resettable TOT OPERA-
TE TIME counter displays total hours of use since the Sparx10 was manufactured.
Temperature readouts from the display panel (TEMP BASE LCD) and power supply unit (TEMP
BASE PS) in the base as well as the driver (TEMP HEAD DRV) and LED PCB (TEMP HEAD LED)
in the head are available. In each case, you can view the current temperature and the maximum
temperature reached since the readout was last reset individually. The TEMP HEAD LEDs views
the actual temperature of the single LEDs.

Preload Demo:
The Sparx10 provides 20 pre-programmed Effects in the Preload demo menu. The user can load
it an change the values with MODIFY. A quick introducing in the effects of Sparx10 can be done.