Assembly

Disconnect at the plug before carry-

ing out any work on the equipment.

Risk of electric shock!

1. Insert pre-filter:

Put the lip seal (15a) of the pre-

filter (15) over the edge of the

metal container (10) (see small

image).

2. Check that the pleated filter

(

 

13) and metal filter cage

(

 

14) are sitting correctly and

securely.

3. Place the container lid (5) on

the metal container (10) and

close it using the seal clips (8).

4. Connect the suction hose (11).

To do this, insert the rotatable

plastic end piece (with the

printed symbol) into the

hose connection (7) and

screw it tight (bayonet con-

nection).

When assembling/detaching the

suction hose, hold the black plastic

end piece and not the metal suction

hose. Twisting or bending could

damage the hose.

5. Plug the suction tube (12) onto

the rigid end piece of the suc-

tion hose (11).

Switching on/off

Connect the mains plug.

The equipment is fitted with a safety

stop, which allows operation only

with the pleated filter and metal

filter cage installed correctly.

Switching On:

On/Off Switch (see

6) In position “I

Switching Off:

On/Off Switch (see

6) In position “0

Operating Instructions

The vacuuming of glowing

embers and of materials that

are combustible, explosive or

harmful to health is prohib-

ited.

There is a risk of injury!

• Place the equipment on a level surface

that is not heat sensitive.

• Use the pre-filter (15) when vacuum-

ing fine, cold ashes or dust in order to

protect the metal filter cage (14) and

the folded filter (13) against contami-

nation.

• The pre-filter (15) can be removed to

vacuum coarse dirt. This increases the

suction power.

• Always use the suction tube for vacu-

uming. In case of minor contamination,

hold the suction pipe approx. 1 cm

above the ash. Remove large ash vol-

umes by directly immersing the suction

pipe.

• Vacuum only cooled ash at less than

40°C.

• When vacuuming, keep checking the

metal container and suction hose for

rises in temperature.

• In the event of a rise in temperature,

switch off the equipment and discon-

nect at the plug. Place the equipment

outside and monitor it as it cools.

• During breaks, you can place the suc-

tion hose (

 

12) in the suction tube

holder (

 

2) on the container lid.

• Always use the carry handle (

4a)

for transporting the equipment.

• The metal container may be filled to