Trouble shooting, Gb ie cy – Parkside PNTS 1500 B3 Benutzerhandbuch

Seite 14

Advertising
background image

14

GB IE

CY

Trouble shooting

Problem

Possible cause

Fault correction

Device does not start

Mains voltage is not

present

Check plug socket, cable, line,

plug and fuse, where appropriate,

repair through electrical specialist

Defective on/off switch

(

10)

Repair through customer service

Worn carbon brushes
Defective motor

Low or lack of

suction

Hose system (

18/19) or

jets (

21-24) blocked

Remove obstructions and blockages

Air control on the handle

(

15) open

Close the air control

Collector (

5) open

Close collector

Collector (

5) full

Empty collector

Filter (

11/12/13) full

or clogged

Empty, clean or replace filter

Float does not switch

the appliance off

Float cannot move

Release float

Float faulty

Repair by Customer Care