Marmitek AWM2 Benutzerhandbuch

Seite 10

Advertising
background image

Usage of the MicroModules in a 3 phase installation.

The X10 transmitters of the MicroModules transmit the command
only once for use in the phase of which they are connected. When
you want to receive the commands on your other phases as well, you
will need to install the CAT3000 phase coupler/repeater.

Technical specifications

Power

230V, 50Hz

Supply current

< 30 mA capacitive

Appliance module

16 A

Signal transmission

> 5Vpp in 5Ohm at 120 kHz ±1 kHz
according to EN50065-1, EN50065-2-1,
EN50065-4-1

X10 transmission

1 pulse burst at 0° and 180°

Signal sensitivity

25mVpp … 6Vpp at 120 kHz ± 4kHz

Signal to Noise ratio

1,35 : 1

Connections

up to 2,5 mm

2

Approvals

NEN-EN-IEC 60669-2-1 and
NEN-EN-IEC 60669-2-2

Made in Holland

10

MARMITEK

Advertising