Problem

Possible cause

Solution

The door is not closed correctly.

Refer to "Closing the door".

The temperature regulator is not set

correctly.

Set a higher temperature.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".

3. If necessary, replace the defective door gaskets.

Contact the Service Center.

Technical data

Dimension of the recess

Height

880 mm

Width

560 mm

Depth

550 mm

Rising Time

20 h

Voltage

230-240 V

Frequency

50 Hz

The technical information are situated in the rating plate

on the internal left side of the appliance and in the energy

label.

Installation

Caution! Read the "Safety Information" carefully for

your safety and correct operation of the appliance

before installing the appliance.

Positioning

Install this appliance at a location where the ambient tem-

perature corresponds to the climate class indicated on the

rating plate of the appliance:

Climate

class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Electrical connection

Before plugging in, ensure that the voltage and frequency

shown on the rating plate correspond to your domestic

power supply.

The appliance must be earthed. The power supply cable

plug is provided with a contact for this purpose. If the do-

mestic power supply socket is not earthed, connect the

appliance to a separate earth in compliance with current

regulations, consulting a qualified electrician.

The manufacturer declines all responsibility if the above

safety precautions are not observed.

This appliance complies with the E.E.C. Directives.