Burkert Type 8112 Benutzerhandbuch
Seite 7

-
T3 with temperature adapter
-50 … +200 °C
-
T2, T1 with temperature adapter
-50 … +250 °C
O
n the electronics - category 1/2G or 2G
Temperature class
-
T6
-40 … +67 °C
-
T5
-40 … +82 °C
-
T4, T3, T2, T1
-40 … +90 °C
3
.2.2
P
ermissible operating pressure in range of the sensor
C
ategory 1/2G
Operating pressure
0
.8 … 1.1
bar
C
ategory 2G
Operating pressure
Vaccum … 64 bar (if necessary nominal
pressure of the process connection element)
I
nformation:
The application conditions mentioned before also apply to LEVEL SWITCH LS8112.
C******N* with lock fitting ARV8112.2** (Pmax. 16 bar, Tmax. 150 °C), ARV8112.3**
(P
max. 64 bar, Tmax. 250 °C).
3
.3 P
ermissible differing application conditions
The LEVEL SWITCH LS8111C******N*, LEVEL SWITCH LS8112C******N* (also with lock
fi
tting ARV8112.***) can also be operated as category 1/2G instrument according to the
conditions mentioned below.
T
emperature class
T
emperature on the sen-
sor
A
mbient temperature on
the electronics
P
rocess pressure
T4, T3, T2, T1
-20 … +60 °C
-40 … +90 °C
0
… 6
bar
N
ote:
If the application conditions (as mentioned before) on the sensor differ, and LEVEL
SWITCH LS8111C******N*, LEVEL SWITCH LS8112C******N* is used as category
1
/2G
instrument, please make sure that the sensor (even in case of failure) has no
own heating and that the safe operation of the equipment in respect to pressures/
temperatures of the materials used, is subject to the user.
The permissible pressures and temperatures for operation are mentioned in the
operating instructions manuals.
LEVEL SWITCH LS8111.C******N*; LEVEL SWITCH LS8112.C******N*
7
32845
-
EN
-
070615