Installation position distance to image center – WolfVision VZ-C32 3 Installation Benutzerhandbuch
Seite 5

A difference between Ceiling- and "Desktop-"Visualizers is that the size of the smallest and largest image
the unit can pick up is not fixed. This depends on how high above the working surface the Visualizer is
mounted. It is very important to know which image sizes you would like to pick up with the Ceiling
Visualizer before installing the unit, in order to correctly calculate the respective mounting height.
Please refer to the calculation program on WolfVision's homepage (see page 5).
The following table shows the distance which is
called "x" in the illustration on the right side:
18°
Distance (refer to tables opposite)
206 mm
8.11 inch
452 mm / 17.8 inch
x
suspended ceiling
(if required)
ceiling
Speaker
x mm = distance * tan 18° - 291mm
x" = distance * tan 18° - 11.45"
(tan 18° = 0.3249)
In extremely high rooms the smallest image the
unit can pick-up may not be small enough. In
such cases a standard ceiling mount or
projector-lift can be used to suspend the Ceiling
Visualizer further from the ceiling.
INSTALLATION POSITION
Distance to image center
87,5 mm / 344"
y
IMPORTANT:
The center of the image is offset 87.5 mm (3.5 ") to the
right, from the middle of the Visualizer housing !
in mm
in mm
in Inch
in Inch
1,100
66
44
2.84
1,200
99
50
4.79
1,400
164
60
8.04
1,600
229
70
11.28
1,800
294
80
14.53
2,000
359
90
17.78
2,200
424
100
21.03
2,400
489
110
24.28
2,600
554
120
27.53
2,800
619
130
30.78
3,000
684
140
34.03
3,200
749
150
37.28
3,400
814
160
40.53
3,600
879
170
43.78
3,800
944
180
47.03
4,000
1,009
190
50.27
4,200
1,074
200
53.52
4,400
1,139
4,600
1,204
4,800
1,269
5,000
1,334
Distance
Visualizer to
working
surface
Distance
Visualizer-
front to
image center
Distance
Visualizer-
front to
image center
Distance
Visualizer to
working
surface
Audience
4