Table 2: Guide value table for PE-HD pursuant to DVS 2207 T1 (09/2005):
Pipe outer Heating timeHeating time Positioning
Cooling time
holding total
(sec) (min)
diameter SDR
6 – 7,4 - 11
SDR
17
(mm) (sec)
(sec)
(sec)
16 5
4
6
2
20
5
4
6
2
25 7
4
10
2
32
8
6
10
4
40 12
6
20
4
50
18
6
20
4
63 24
8
30
6
75
30
18
8
30
6
90 40
26
8
40
6
110
50
36
10
50
8
125 60
46
10
60
8
Table 3: Guide value table for PP pursuant to DVS 2207 T11 (08/2008):
Pipe outer Heating timeHeating time Positioning
Cooling time
holding total
(sec) (min)
diameter SDR
6 – 7,4 - 11
SDR
17 – 17,6
(mm) (sec)
(sec)
(sec)
16 5
4
6
2
20
5
4
6
2
25 7
4
10
2
32
8
6
10
4
40 12
6
20
4
50
18
6
20
4
63 24
10
8
30
6
75
30
15
8
30
6
90 40
22
8
40
6
110
50
30
10
50
8
125 60
35
10
60
8
Table 4: Guide value table for PVDF pursuant to DVS 2207 T15 (12/2005):
Pipe outer
min. pipe Heating time Positioning
Cooling time
holding total
(sec) (min)
diameter wall
thickn.
(mm) (mm)
(sec)
(sec)
16 1,5
4
4
6
2
20
1,9
6
4
6
2
25 1,9
8
4
6
2
32
2,4
10
4
12
4
40 2,4
12
4
12
4
50
3,0
18
4
12
4
63 3,0
20
6
18
6
75
3,0
22
6
18
6
90 3,0
25
6
18
6
110
3,0
30
6
24