3330872.01 02/2014 GB/D

Explosion protection, power supply

Only for connection to a certified intrinsically safe circuit with the following

maximum values:

Maximum terminal voltage U

0

DC 30 V

Maximum current l

0

100 mA

Maximum power P

0

1 W

Maximum capacitance C

i

negligibly small

Maximum inductance L

i

negligibly small

Ambient conditions

Operating temperature

Standard version: 0 ... 80 °C

Ex version: 0 ... 60 °C

Storage temperature

-20 ... +80 °C

Module housing

Dimensions

Ø 43.0 / 48.5 / 62.5 mm x 37 mm

Case material

Polycarbonate

Ingress protection

Front: IP 67

Connection: IP 20 or IP 00

Weight

approx. 55 g

Connection

Plug-in terminal strip, up to 1.5 mm²

open cable ends

Programmable features

Scale range, display time, decimal point,

unit (°C/°F), zero point stabilisation,

programming lock, reference points, TAG

number

Case designs

(see chapter 4.2)

Connection head (standard)

Wall-mount case

Case with pipe support

CE conformity

EMC directive

2004/108/EC, EN 61326 emission

(group 1, class A) and interference

immunity (industrial application)

ATEX directive

94/9/EC, II 2 G Ex ia IIC T6

For further specifications see WIKA data sheet AC 80.11 and the order

documentation.