Information on mounting and operation in – WIKA DIH10-Ex Benutzerhandbuch

Seite 24

Advertising
background image

GB

24

WIKA operating instructions model DIH10-Ex

3330872.01 02/2014 GB/D

Use only appropriate intrinsically safe equipment with a

separate EC-type examination certificate, with which the

permissible electrical limit values of the intrinsically safe

circuit will not be exceeded.

Max. terminal voltage U

0

= DC 30 V

Max. current l

0

= 100 mA

Max. power P

0

= 1 W

The maximum effective capacitance and inductance are

negligibly small.

WARNING!

The ambient temperature of the current-loop display can

be altered by additional components (e.g. through heat

dissipation in the case, in particular with a transmitter

mounted within the case or by mounting it in the connection

head of a temperature sensor with the radiated heat from

the process medium). The operator of the display must

ensure that, even in the event of a failure, the maximum

permitted ambient temperature of 60 °C is not exceeded.

The programming set for the factory programming must

only be used by the manufacturer, as it does not have

ATEX approval!

The programming of the display must only be made via the

three buttons at the rear of the display!