Commissioning ... / 7. information on – WIKA DIH10-Ex Benutzerhandbuch

Seite 23

Advertising
background image

GB

WIKA operating instructions model DIH10-Ex

23

3330872.01 02/2014 GB/D

6.3.3 Display information, Overrange/underrange

Range:

4 ... 20 mA

Displayed range:

3.9 ... 20.1 mA

Usable range:

3.6 ... 21.5 mA

Advance warning of underrange: 3.6 ... < 3.9 mA

Advance warning of overrange:

> 20.1 ... 21.5 mA

Underrange displayed:

< 3.6 mA

Overrange displayed:

> 21.5 mA

With the advance warning, the display blinks (normal display

alternates with horizontal bars).

For values under 3.6 mA, a horizontal bar alternates with the display

"undr". For values over 21.5 mA, a horizontal bar alternates with the

display "over".

7. Information on mounting and operation in

hazardous areas

WARNING!

As a general rule, repairs are strictly prohibited.

Displays with externally visible damage should not be

used. Observe the following instructions for mounting

and operation as well as the requirements for using the

instruments in hazardous areas.

In addition to these operating instructions, note

the accompanying EC-type examination certificate

(ZELM 05 ATEX 0260).

Do not make any alterations to the display.

6. Commissioning ... / 7. Information on ...

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: