Global Drive Oscilloscope
L
24
GDO DE/EN 1.1
4
Recording curve
Note!
If the oscilloscope is integrated into the IEC 61131 program (DDS ), it permanently requires a computing
time of 100
ms. It must be checked in the task monitor, that enough computing capacity is available.
Select from the DDS the menu command
Online
W
Communication parameters. The communication
channel Lenze OPC must be selected from the dialog box communication parameters.
Drive Developer Studio (DDS)
1. Select from the windows start menu
Programs
W
Lenze
W
Drive Developer Studio
W
Drive PLC Developer Studio
2. Select from the DDS the menu command
File
W
Open.
Open with the windows dialog the project GDO.pro in the DDS project directory.
3. Select from the DDS the menu command
Project
W
Compile or press <F11>.
Though compiling a file with the ending
*.sdb (GDO.sdb) is created. It will be needed later in GDO.
4. Start the program in the target system.
Select from the DDS the menu command
Online
W
Log in and start the program.
Global Drive Oscilloscope (GDO)
1. Select from the windows start menu
Programs
W
Lenze
W
GlobalDriveOscilloscope
W
GlobalDriveOscilloscope
The GDO window appears.
2. Select from GDO the menu command
File
W
Connect or press the button Connection device.
Opening the dialog box select device can take a few seconds.
3. Open in the dialog box select device the online path completely and mark a target system.
(e. g. Drive: 65: Servo PLC 9300)
Then press the button
OK.
By pressing the button
Cancel the process is completed.
By pressing the button
Help a detailed HTML online help is called up.
4. If you have pressed in the dialog box select device the button
OK, the dialog box select DDS
project symbol file will appear. Mark in dialog box the project SDB file (GDO.sdb) which has
been created previously in the DDS. Then press the button
OK.