66 s sp pe ec ciiffiic ca attiio on ns s – Weidmuller Advanced Line Managed Switch Benutzerhandbuch
Seite 22

22
6
6 S
Sp
pe
ec
ciiffiic
ca
attiio
on
ns
s
E
EM
MC
C
EN 61000-4-2 (ESD) 6kV/8kV
EN 61000-4-3 (radiated immunity)
ENV 50204 @AM 10V/average 80MHz - 1GHz
EN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kV
EN 61000-4-5 (surge) 2/1kV
EN 61000-4-6 (conducted immunity)
ENV 50204 @10V 150kHz - 80MHz
EN 61000-4-11
EN 61000-4-29 (voltage variation)
EN 55022 (HF E)
conducted emissions 150kHz - 30MHz
radiated emissions 30MHz - 1GHz pp/average
radiated emissions 30MHz - 1GHz pp/qp
S
Sh
ho
oc
ck
k-- u
un
nd
d v
viib
brra
attiio
on
n--tte
es
stt
IEC 60068-2-6 sinusoidal vibrations
frequencies: 5-9 Hz, amplitude: 3.5 mm
frequencies: 9-150 Hz, acceleration: 1g
IEC 60068-2-27 shock test, half-sinusoidal
shock acceleration: 15g (operating) 30g (non operating)
shock period: 11ms
E
En
nv
viirro
on
nm
me
en
ntt--tte
es
stt
IEC 60068-2-1 & IEC 60068-2-2
operating -40°C ... 75°C
non operating -40°C ... 75°C
IEC 60068-2-14 thermal shock
operating 0°C ... 60°C
non operating -40°C ... 80°C
IEC 60068-2-30 damp heat
C
Ce
errttiiffiic
ca
attiio
on
ns
s
UL Listed Industrial Control Equipment, certified1 for US and
Canada.
CE marking within the EU
GOST R-certification (IEC standards with Russian deviations)
C
Clla
as
ss
s II D
Diiv
viis
siio
on
n 2
2
This equipment is suitable for use in Class I Division 2, Groups A,
B, C, and D or Non-Hazardous locations only.
Germanischer Lloyd (GL)