55 s sp pe eiiffiic ca attiio on ns s – Weidmuller Advanced Line Unmanaged Switch Benutzerhandbuch

Seite 22

Advertising
background image

22

5

5 S

Sp

pe

eiiffiic

ca

attiio

on

ns

s

E

EM

MV

V

EN 61000-4-2 (ESD) 6kV/8kV
EN 61000-4-3 (radiated immunity)
ENV 50204 @AM 10V/average 80MHz - 1GHz
EN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kV
EN 61000-4-5 (surge) 2/1kV
EN 61000-4-6 (conducted immunity)
ENV 50204 @10V 150kHz - 80MHz
EN 61000-4-11
EN 61000-4-29 (voltage variation)
EN 55022 (HF E)
conducted emissions 150kHz - 30MHz
radiated emissions 30MHz - 1GHz pp/average
radiated emissions 30MHz - 1GHz pp/qp

S

Sh

ho

oc

ck

k-- u

un

nd

d v

viib

brra

attiio

on

n--tte

es

stt

IEC 60068-2-6 sinusoidal vibrations
frequencies: 5-9 Hz, amplitude: 3.5 mm
frequencies: 9-150 Hz, acceleration: 1g
IEC 60068-2-27 shock test, half-sinusoidal
shock acceleration: 15g (operating) 30g (non operating)
shock period: 11ms

E

En

nv

viirro

on

nm

me

en

ntt--tte

es

stt

IIEC 60068-2-1 & IEC 60068-2-2
operating -40°C ... 75°C
non operating -40°C ... 75°C
IEC 60068-2-14 thermal shock
operating 0°C ... 60°C
non operating -40°C ... 80°C
IEC 60068-2-30 damp heat

22

C

Ce

errttiiffiic

ca

attiio

on

ns

s

UL Listed Industrial Control Equipment, certified1 for US and
Canada. .

CE marking within the EU

GOST R-certification (IEC standards with Russian deviations)

C

Clla

as

ss

s II D

Diiv

viis

siio

on

n 2

2

This equipment is suitable for use in Class I Division 2, Groups A,
B, C, and D or Non-Hazardous locations only.

Germanischer Lloyd (GL)

Advertising