Weidmuller IP 67 Switch Benutzerhandbuch

Seite 17

Advertising
background image

17

2

2..5

5 P

Po

ow

we

err s

su

up

pp

plly

y

Supply voltage

10 ... 35 V DC / 10 ... 24 V AC

Rating

5 W

C

Ca

au

uttiio

on

n

Insecure outputs. Operations on the IE-SW8-M-IP67 only realise by qualified em-
ployees. Use a power supply unit according to DIN EN 60742 (VDE 0551). Secure
all electrical outputs.

- The switch operates with Auto-MDIX technology, so straight-through or crossover
cables can be used to connect network interfaces or other network devices.

- The chassis connecting serves as an additionally ground.

supply voltage
- AUX M12 pin
A-keyed

PIN 1: + 24 V DCUI1
PIN 2: + 24 V DC UI2
PIN 3: GND UI
PIN 4: GND UI
PIN 5: PE

0

suplly voltage
- AUX M12 connector
A-keyed

PIN 1: + 24 V DC UI1
PIN 2: + 24 V DC UI2
PIN 3: GND UI
PIN 4: GND UI
PIN 5: PE

0

Ethernet connector
- Ports M12 D-keyed

PIN 1: Transmission data + (TD+)
PIN 2: Transmission data - (RD+)
PIN 3: Receiver data + (TD-)
PIN 4: Receiver data - (RD-)
Shield over metallic tread connected with
functional earth

RS232
M12 B-keyed connec-
tor

PIN 1: n.c.
PIN 2: TxD
PIN 3: GND Data
PIN 4: RxD
PIN 5: FE

Relais contact
M12 A-keyed connec-
tor

Pin 1: +24 V DC
PIN 2: relais contact 2 (potentional free)
PIN 3: GND
PIN 4: relais contact 1 (potentional free)
PIN 5: PE

In all power schemes a fuse of 4 A slow is required in the power supply lines.