Cadis™ manual 1.0, Technical data firnet™ controller – HK Audio CAD 208 Benutzerhandbuch
Seite 24

Cadis™ Manual 1.0
Technical Data FirNet™ Controller
Connector Analog Input
3-pol. XLR female
Pin assignments
1 = ground, 2 = Signal(+), 3 = Signal(-)
Input impedance
9 k-ohm
Maximum input level
Variable; 6, 12, 18, and 24 dBu
Dynamic range, input
>128 dB (A)
Digital input
3-pol. XLR female
Pin assignments
1 = ground, 2 = Signal, 3 = Signal
Input impedance
110 ohms
Protocol
AES 3 (AES/EBU)
Clock rate
48 or 96 kHz, and 96 kHz internal
Synchronization
To an external source (slave mode)
Digital output
3-pol. XLR male
Pin assignments
1 = ground, 2 = Signal, 3 = Signal
Output impedance
110 ohms
Protocol
AES 3 (AES/EBU)
Signal processing
Refresh signal form and level (Bypass at power failure)
Analog outputs
3-pol. XLR male
Pin assignments
1 = ground, 2 = Signal(+), 3 = Signal(-)
Output impedance
35 ohms
Maximum output level
Variable; 6, 12, 18, and 24 dBu
Dynamic range, output
>125 dB(A)
Mains voltage connector
Three-pole non-heating equipment connector
Mains voltage / frequency
100 to 240 V / 50 - 60 Hz
Power consumption
40 VA
Max. curr. cons. at 100 V mains voltage
400 mA
Max. curr. cons. at 230 V mains voltage
175 mA
Ethernet X port
RJ-45, RJ-45, cross-connected
Ethernet II port
RJ-45, RJ-45, direct-connected
Audio data (Linear Through mode)
Frequency response (-1 dB)
5.5 Hz to 34 KHz
THD+N (20 Hz bis 20 kHz)
AD>DA input level 21 dBu,
R=100 k, 96 kHz 0,0012%-0,0013%
AES>DA input level -3dB FS,
R=100k, 96 kHz 0,0010% - 0,0012%
Latency (incl. limiter):
AD > DA 96 KHz 3,15 ms
AD > AES/EBU 96 KHz
AES/EBU > A 96 KHz
+ FIR filter
5.8 ms (Cohedra / Coh. Compact)
Internal sampling rate
96 kHz
Internal data format
32 bit floating point
AD converter resolution
28 Bit
DA converter resolution
24 Bit
Temperature range
-10° C to +70°C
Weight
3 kg • 6.,6 lbs.
Measurements (D x H x W)
48 x 4.4 x 23.2 cm
18-7/8 x 17-5/16 x 9-1/8"