Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC * (HTL-P, TTL)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
300...5000 (As ordered)
•
Phase shift:
90° ±20°
•
Scan ratio:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz
≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted
•
Output stages:
HTL-P (power linedriver)
TTL/RS422
(As ordered)
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approvals:
CE, UL approval / E256710
9.2
Technical data - mechanical design
•
Size (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft
•
Shaft loading:
≤300 N axial; ≤450 N radial
•
Flange:
EURO flange B10
•
Protection IEC 60529:
IP66
•
Operating speed:
≤12000 rpm (mechanical)
•
Operating torque typ.:
2 Ncm
•
Rotor moment of inertia:
200 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-40…+100 °C
-25…+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
•
Resistance:
IEC 60068-2-6:2007
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 200 g, 6 ms
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
•
Connection:
ITT Cannon connector (2x with option G)
•
Weight approx.:
1.9 kg
2.5 kg (with option G)
* The voltage supply is 9...26 VDC at TTL - version R for versions with a resolution <95 steps/turn