11 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer HOG 28 M Benutzerhandbuch
Seite 29: Technical data, Technical data - electrical ratings, Technical data - mechanical design

MB178T2 - 11081759
Baumer_HOG28-T2_II_DE-EN (14A1)
26
Technical data
11
11
Technical data
11.1
Technical data - electrical ratings
• Voltage supply:
9...26 VDC (HTL - version C, TTL - version R)
5 VDC ±5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
1024...2048 (As precised on order)
• Phase shift:
90° ±20°
• Duty cycle:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
• Output signals:
K1, K2, K0 + inverted
• Output stage:
HTL
TTL/RS422
(As precised on order)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS, UL approval / E256710
11.2
Technical data - mechanical design
• Size (flange):
ø287 mm
• Shaft type:
ø120...150 mm (through hollow shaft)
• Shaft loading:
≤250 N axial
≤320 N radial
• Protection DIN EN 60529:
IP 54
• Operating speed:
≤3600 rpm (mechanical)
• Operating torque typ.:
50 Ncm
• Rotor moment of inertia:
240 kgcm² (ø150)
• Materials:
Housing: aluminium alloy
Shaft: stainless steel
• Operating temperature:
-30…+85 °C
(restricted in potentially explosive environments, see section 2)
• Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 200 g, 6 ms
• Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
• Connection:
Flange connector M23, 12-pin (2x with option M)
• Weight approx.:
20 kg (ш150)