10 technical data, 2 technical data - electrical ratings, 1 technical data - mechanical design – Baumer HOG 86 M Benutzerhandbuch

Seite 43: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB194 - 11072323

Baumer_HOG86-HOG86M_II_DE-EN (14A5)

40

10

Technical data

10.2

Technical data - electrical ratings

• Voltage supply:

9...30 VDC (HTL, TTL - version R)

5 VDC ±5% (TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

500...5000 (As ordered)

• Phase shift:

90° ±20°

• Scan ratio:

45...55 %; 40...60 % (>3072 pulses per revolution)

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output frequency:

≤170 kHz; ≤300 kHz option

• Output signals:

K1, K2, K0 + inverted; Error output (only EMS)

• Output stages:

HTL-P (power linedriver); TTL/RS422 (As ordered)

• Shaft insulation:

2.8 kV

• Transmission length:

≤350 m at 100 kHz (HTL-P); ≤550 m at 100 kHz (TTL)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

CE, UL/CSA approval / E256710

HOG 86 M

• Operating principle:

Redundant sensing

10.1

Technical data - mechanical design

• Size (flange):

ø99 mm

• Shaft type:

ø12...16 mm (blind hollow shaft)

ø17 mm (cone shaft 1:10)

• Shaft loading:

≤350 N axial; ≤450 N radial

• Motor shaft tolerance:

0.2 mm radial

• Protection DIN EN 60529:

IP66

• Operating speed:

≤10000 rpm (mechanical)

• Operating torque:

≤6 Ncm

• Rotor moment of inertia:

160 gcm

2

• Materials:

Housing: aluminium; Shaft: stainless steel

• Resistance:

IEC 60068-2-6:2007, Vibration 20 g, 10-2000 Hz

IEC 60068-2-27:2008, Shock 250 g, 6 ms

• Corrosion protection:

IEC 60068-2-52 salt mist complies to

ISO 12944-5:1998 protective paint systems (C4)

• Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

HOG 86

• Operating temperature:

-40**…+100°C, -40**...+90 °C (fixed cable)

Restricted in potentially explosive environments, see section 2.

• Connection:

Terminal box, flange connector M23, 12-pin, cable 1 m

• Weight approx.:

1.3 kg

HOG 86 M

• Operating temperature:

-40**…+100°C

Restricted in potentially explosive environments, see section 2.

• Connection:

2x terminal box

• Weight approx.:

1.4 kg

** Up to -25 °C for versions >3072 pulses per revolution