10 technical data, 2 technical data - electrical ratings, 1 technical data - mechanical design – Baumer HOG 86 M Benutzerhandbuch
Seite 43: Technical data, Technical data - electrical ratings, Technical data - mechanical design

MB194 - 11072323
Baumer_HOG86-HOG86M_II_DE-EN (14A5)
40
10
Technical data
10.2
Technical data - electrical ratings
• Voltage supply:
9...30 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
500...5000 (As ordered)
• Phase shift:
90° ±20°
• Scan ratio:
45...55 %; 40...60 % (>3072 pulses per revolution)
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤170 kHz; ≤300 kHz option
• Output signals:
K1, K2, K0 + inverted; Error output (only EMS)
• Output stages:
HTL-P (power linedriver); TTL/RS422 (As ordered)
• Shaft insulation:
2.8 kV
• Transmission length:
≤350 m at 100 kHz (HTL-P); ≤550 m at 100 kHz (TTL)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, UL/CSA approval / E256710
HOG 86 M
• Operating principle:
Redundant sensing
10.1
Technical data - mechanical design
• Size (flange):
ø99 mm
• Shaft type:
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
• Shaft loading:
≤350 N axial; ≤450 N radial
• Motor shaft tolerance:
0.2 mm radial
• Protection DIN EN 60529:
IP66
• Operating speed:
≤10000 rpm (mechanical)
• Operating torque:
≤6 Ncm
• Rotor moment of inertia:
160 gcm
2
• Materials:
Housing: aluminium; Shaft: stainless steel
• Resistance:
IEC 60068-2-6:2007, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008, Shock 250 g, 6 ms
• Corrosion protection:
IEC 60068-2-52 salt mist complies to
ISO 12944-5:1998 protective paint systems (C4)
• Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
HOG 86
• Operating temperature:
-40**…+100°C, -40**...+90 °C (fixed cable)
Restricted in potentially explosive environments, see section 2.
• Connection:
Terminal box, flange connector M23, 12-pin, cable 1 m
• Weight approx.:
1.3 kg
HOG 86 M
• Operating temperature:
-40**…+100°C
Restricted in potentially explosive environments, see section 2.
• Connection:
2x terminal box
• Weight approx.:
1.4 kg
** Up to -25 °C for versions >3072 pulses per revolution
Technical data