9 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer HOGS 14 Benutzerhandbuch

Seite 25: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB094 - 11055703

Baumer_HOGS14_II_DE-EN (13A3)

22

Technical data

9

9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:

5 VDC ±5 % (version DN ...)

9...26 VDC (version DN ... R)

• Consumption w/o load:

≤90 mA

• Sinewave cycles per turn:

1024...5000 (As precised on order)

• Phase shift:

90°

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output signals:

K1, K2, K0 + inverted

• Output stage:

SinCos 1 Vpp

• Difference of SinCos amplitude:

≤20 mV

• Harmonics typ.:

-50 dB

• DC offset:

≤20 mV

• Bandwidth:

200 kHz (-3 dB)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

UL approval / E256710

9.2

Technical data - mechanical design

• Size (flange):

ø158 mm

• Shaft type:

ø40...75 mm (through hollow shaft)

• Shaft loading:

≤150 N axial

≤200 N radial

• Protection DIN EN 60529:

IP 55

• Operating speed:

≤6300 rpm

• Operating torque typ.:

15 Ncm

• Rotor moment of inertia:

16.5 kgcm² (ø70)

• Materials:

Housing: aluminium

Shaft: stainless steel

• Operating temperature:

-30...+85 °C

(restricted in potentially explosive environments, see

section 2, operation -30...-20 °C at constant temperature)

• Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 6 ms

• Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIB T135°C Dc (dust)

• Connection:

Terminal box

• Weight approx.:

2,5 kg

Advertising