9 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer HOGS 100 Benutzerhandbuch

Seite 27: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB183aT1 - 11081756

Baumer_HOGS100-R-T1_II_DE-EN (13A2)

24

Technical data

9

9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:

5 VDC ±10 % (version DN ...)

9...30 VDC (version DN ... R)

• Consumption w/o load:

≤90 mA

• Sinewave cycles per turn:

720...5000 (As precised on order)

• Phase shift:

90°

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output signals:

K1, K2, K0 + inverted

• Output stage:

SinCos 1 Vpp

• Difference of SinCos amplitude:

≤20 mV

• Harmonics typ.:

-50 dB

• DC offset:

≤20 mV

• Bandwidth:

250 kHz (-3 dB)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

UL approval / E256710

9.2

Technical data - mechanical design

• Size (flange):

ø105 mm

• Shaft type:

ø12...20 mm (blind hollow shaft)

ø17 mm (cone shaft 1:10)

• Shaft loading:

≤450 N axial

≤600 N radial

• Protection DIN EN 60529:

IP 66

• Operating speed:

≤10000 rpm (mechanical)

• Operating torque typ.:

6 Ncm

• Rotor moment of inertia:

180 gcm²

• Materials:

Housing: aluminium die-cast

Shaft: stainless steel

• Operating temperature:

-20...+85 °C

(restricted in potentially explosive environments, see section 2)

• Resistance:

IEC 60068-2-6

Vibration 20 g, 10-2000 Hz

IEC 60068-2-27

Shock 300 g, 6 ms

• Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

• Connection:

Terminal cover

• Weight approx.:

1.6 kg

Advertising