Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
5 VDC ±10 % (version DN ...)
9...30 VDC (version DN ... R)
• Consumption w/o load:
≤90 mA
• Sinewave cycles per turn:
720...5000 (As precised on order)
• Phase shift:
90°
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output signals:
K1, K2, K0 + inverted
• Output stage:
SinCos 1 Vpp
• Difference of SinCos amplitude:
≤20 mV
• Harmonics typ.:
-50 dB
• DC offset:
≤20 mV
• Bandwidth:
250 kHz (-3 dB)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
UL approval / E256710
9.2
Technical data - mechanical design
• Size (flange):
ø105 mm
• Shaft type:
ø12...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
• Shaft loading:
≤450 N axial
≤600 N radial
• Protection DIN EN 60529:
IP 66
• Operating speed:
≤10000 rpm (mechanical)
• Operating torque typ.:
6 Ncm
• Rotor moment of inertia:
180 gcm²
• Materials:
Housing: aluminium die-cast
Shaft: stainless steel
• Operating temperature:
-20...+85 °C
(restricted in potentially explosive environments, see section 2)
• Resistance:
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
• Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
• Connection:
Terminal cover
• Weight approx.:
1.6 kg