Assembly instructions gb – Baumer Cable pull Benutzerhandbuch

Seite 2

Advertising
background image

6

8

7

5

Uncontrolled cable retraction can break off cable fixing

(cable clip or M4 connection).

Any uncontrolled retraction or letting snap of the measu-

ring wire can destroy the cable-pull encoder.

Installation position

- Prefer protected position for cable-pull encoder and

measuring wire.

- Prefer plain installation base or three-point mounting.

- Prefer mounting with measuring wire outlet down-

wards.

- Avoid entry of fluids and dirt through measuring wire

outlet.

- Avoid damage and soiling of measuring wire.

Fixation

- Fix cable-pull encoder at the assembly slots according

to datasheet.

- No tension or damage on housing.

Assembly support loop for difficult conditions
(depends on product)

- During assembly, use additional assembly support loop

to avoid snapping of measuring wire.

- Pull assembly support loop through wire assembly clip

and put it around wrist.

- Prefer fixation of wire assembly clip with retracted

measuring wire.

Danger

Warnings of possible danger.

General instructions

Information on appropriate product handling.

General remarks

Additional information

The installation instruction is supplementary to already

existing documentation (e.g. catalog, data sheet, manual).

It is imperative to read the manual carefully prior to star-

ting the device.

Appropriate use

- The cable-pull encoder is a precision measuring device.

It is explicitly designed for registration of angular posi-

tions and revolutions as well as evaluation and supply

of measuring values as electric output signals for the

subsequently connected device. The cable-pull encoder

must not be used for any other purpose.

Start up

- Installation and assembly of the cable-pull encoder only

by electrically skilled and qualified personnel.

- Consider also the operation manual of the machine

manufacturer.

Safety instructions

- All electrical connections are to be revised prior to star-

ting the system.

- Incorrect assembly and electrical connections or any

other inappropriate work at encoder and system may

lead to malfunction or failure of the encoder.

- Make sure by appropriate safety measures, that in case

of error or failure of the cable-pull encoder, no danger to

persons or damage to machines occurs.

- The cable-pull encoder may be operated only within the

datasheet specifications.

Any disregard may lead to malfunctions, material damage

and personal injury.

Disposal

Components are to be disposed of according to the regu-

lations prevailing in the respective country.

Transport and storing

- Transport and store in original packing only.

- Do not drop or expose cable-pull encoder to major

shocks.

- Do not pull measuring wire and wire assembly clip duri-

ng unpacking of cable-pull encoder.

- Do not remove shipment protection until final mounting

of cable-pull encoder.

Assembly

- Avoid punches or shocks on case and shaft.

- Avoid case distortion.

- Do not open or modify encoder in any mechanical way.

Shaft, bearing, glass disc or electronic componen-

ts might be damaged and a secure operation is no

longer guaranteed.

Electrical installation/connection

- See corresponding mounting instructions for encoder.

Do not let snap measuring wire.
No uncontrolled retraction of measuring wire.
No tear of measuring wire beyond maximum
measurement range.
Pull measuring wire in intended direction only.
No inclined pulling of measuring wire.
Do not damage, oil and grease measuring wire.
Do not bend measuring wire.
Do not tear measuring wire along objects.
Do not loop measuring wire around machine parts or
persons.

Cable-pull for encoder

5-8

Assembly Instructions

GB

Advertising