10 technical data, 1 technical data - electrical ratings (og 70), 2 technical data - electrical ratings (ogs 71) – Baumer OGS 71 Benutzerhandbuch
Seite 30: Technical data, Technical data - electrical ratings (og 70), Technical data - electrical ratings (ogs 71)

27
Baumer_OG70-OGS71_II_DE-EN (13A1)
MB092 - 11055702
10
Technical data
10
Technical data
10.1
Technical data - electrical ratings (OG 70)
• Voltage supply:
9...26 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
100...10000 (as precised on order)
• Phase shift:
90° ±20°
• Duty cycle:
40...60%
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤250 kHz
• Output signals:
K1, K2, K0 + inverted
• Output circuit:
HTL (power linedriver), TTL/RS422
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
UL approval / E256710
10.2
Technical data - electrical ratings (OGS 71)
• Voltage supply:
5 VDC ±10 % (version DN ...)
9...30 VDC (version DN ... R)
• Consumption w/o load:
≤90 mA
• Sinewave cycles per turn:
1024...5000 (like precised on order)
• Phase shift:
90°
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output signals:
K1, K2, K0 + inverted
• Output circuit:
SinCos 1 Vpp
• Difference of SinCos amplitude:
≤20 mV
• Harmonics typ.:
-50 dB
• DC offset:
≤20 mV
• Bandwidth:
250 kHz (-3 dB)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
UL approval / E256710