10 technical data, 1 technical data - electrical ratings (og 70), 2 technical data - electrical ratings (ogs 71) – Baumer OGS 71 Benutzerhandbuch

Seite 30: Technical data, Technical data - electrical ratings (og 70), Technical data - electrical ratings (ogs 71)

Advertising
background image

27

Baumer_OG70-OGS71_II_DE-EN (13A1)

MB092 - 11055702

10

Technical data

10

Technical data

10.1

Technical data - electrical ratings (OG 70)

• Voltage supply:

9...26 VDC (HTL, TTL - version R)

5 VDC ±5% (TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

100...10000 (as precised on order)

• Phase shift:

90° ±20°

• Duty cycle:

40...60%

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output frequency:

≤250 kHz

• Output signals:

K1, K2, K0 + inverted

• Output circuit:

HTL (power linedriver), TTL/RS422

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

UL approval / E256710

10.2

Technical data - electrical ratings (OGS 71)

• Voltage supply:

5 VDC ±10 % (version DN ...)

9...30 VDC (version DN ... R)

• Consumption w/o load:

≤90 mA

• Sinewave cycles per turn:

1024...5000 (like precised on order)

• Phase shift:

90°

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output signals:

K1, K2, K0 + inverted

• Output circuit:

SinCos 1 Vpp

• Difference of SinCos amplitude:

≤20 mV

• Harmonics typ.:

-50 dB

• DC offset:

≤20 mV

• Bandwidth:

250 kHz (-3 dB)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

UL approval / E256710

Advertising