8 technical data, 1 technical data - electrical ratings, 2 technical data - electrical ratings (encoder) – Baumer POG 90 + ESL Benutzerhandbuch

Seite 28: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (encoder), Technical data - electrical ratings (speed switch)

Advertising
background image

25

Baumer_POG90-ESL_II_DE-EN (14A1)

MB154.2 - 11067531

8

Technical data

8

Technical data

8.1

Technical data - electrical ratings

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

POG 90 + ESL 90
• Approvals:

CE, RoHS

8.2

Technical data - electrical ratings (encoder)

• Voltage supply:

9...30 VDC

(HTL, TTL - version R)

5 VDC ±5 %

(TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

1024...10000 (As precised on order)

• Phase shift:

90° ±8°

• Duty cycle:

44...56 %

• Reference signal:

Zero pulse, width 90°

• Output frequency:

≤250 kHz

• Output signals:

K1, K2, K0 + inverted

• Output stage:

HTL

TTL/RS422

(As precised on order)

• Sensing method:

Optical

8.3

Technical data - electrical ratings (speed switch)

• Switching accuracy:

±4 % (≤1500 rpm)

±2 % (>1500 rpm)

• Switching hysteresis:

≤30 % of switching speed

• Switching delay time:

≤40 ms

POG 90 + ESL 90
• Switching outputs:

1 output, speed control

• Output switching capacity:

≤6 A / 250 VAC

≤1 A / 48 VDC

• Minimum switching current:

100 mA

POG 90 + ESL 93
• Voltage supply:

12 VDC ±10 %

• Consumption w/o load:

≤5 mA

• Switching outputs:

3 outputs, speed control

• Current each output:

40 mA (DC)

Advertising