Technical data

9

Technical data

9.1

Technical data - electrical ratings

• Consumption w/o load:

≤200 mA

HOG 10 + DSL.E
• Voltage supply:

9...30 VDC

HOG 10 + DSL.R
• Voltage supply:

15...30 VDC

9.2

Technical data - electrical ratings (encoder)

• Pulses per revolution:

512...2500 (As precised on order)

• Phase shift:

90° ±20°

• Duty cycle:

40...60 %

• Reference signal:

Zero pulse, width 90°

• Output frequency:

≤120 kHz

• Output signals:

K1, K2, K0 + inverted

• Output stage:

HTL

TTL/RS422

(As precised on order)

• Sensing method:

Optical

9.3

Technical data - electrical ratings (speed switches)

• Interface:

RS485

• Switching accuracy:

±2 % (Digit)

• Switching delay time:

≤40 ms

HOG 10 + DSL.E
• Switching outputs:

2 outputs, speed control

1 control output

• Output switching capacity:

5...230 VAC/VDC; 5...250 mA

HOG 10 + DSL.R
• Switching outputs:

3 outputs, speed control

• Output switching capacity:

12 VDC; ≤40 mA

Advertising