9 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer AG 14 Benutzerhandbuch
Seite 19: Technical data, Technical data - electrical ratings, Technical data - mechanical design
MB146 - 11055759
Baumer_AG14_II_DE-EN (14A1)
16
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
9...26 VDC (HTL, TTL - version R)
5 VDC ±5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
250...2500 (As precised on order)
• Phase shift:
90° ±20°
• Duty cycle:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
• Output signals:
K1, K2, K0 + inverted
• Output stage:
HTL
TTL/RS422
(As precised on order)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS, UL approval / E256710
9.2
Technical data - mechanical design
• Size (flange):
ø139 mm
• Shaft type:
ø70 mm (through hollow shaft)
• Shaft loading:
≤75 N axial
≤150 N radial
• Protection DIN EN 60529:
IP 54
• Operating speed:
≤3500 rpm (mechanical)
• Operating torque typ.:
10 Ncm
• Rotor moment of inertia:
7.1 kgcm
2
• Material:
Aluminium, bare
• Operating temperature:
-20...+85 °C
• Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 11 ms
• Connection:
Flange connector M23, 12-pin
• Weight approx.:
1.3 kg