9 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer AG 14 Benutzerhandbuch

Seite 19: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB146 - 11055759

Baumer_AG14_II_DE-EN (14A1)

16

Technical data

9

9

Technical data

9.1

Technical data - electrical ratings

Voltage supply:

9...26 VDC (HTL, TTL - version R)

5 VDC ±5 % (TTL)

Consumption w/o load:

≤100 mA

Pulses per revolution:

250...2500 (As precised on order)

Phase shift:

90° ±20°

Duty cycle:

40...60 %

Reference signal:

Zero pulse, width 90°

Sensing method:

Optical

Output frequency:

≤120 kHz

Output signals:

K1, K2, K0 + inverted

Output stage:

HTL

TTL/RS422

(As precised on order)

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, RoHS, UL approval / E256710

9.2

Technical data - mechanical design

Size (flange):

ø139 mm

Shaft type:

ø70 mm (through hollow shaft)

Shaft loading:

≤75 N axial

≤150 N radial

Protection DIN EN 60529:

IP 54

Operating speed:

≤3500 rpm (mechanical)

Operating torque typ.:

10 Ncm

Rotor moment of inertia:

7.1 kgcm

2

Material:

Aluminium, bare

Operating temperature:

-20...+85 °C

Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 11 ms

Connection:

Flange connector M23, 12-pin

Weight approx.:

1.3 kg

Advertising