10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer POG 90 - Version B10 Benutzerhandbuch
Seite 27: Technical data, Technical data - electrical ratings, Technical data - mechanical design

MB154 - 11055767
Baumer_POG90_II_DE-EN (14A2)
24
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
1024...10000 (As precised on order)
•
Phase shift:
90° ±8°
•
Scan ratio:
46...56 %
•
Reference signal:
Zero pulse, width 90°
(width 180° at special version POG 90 ... N)
•
Sensing method:
Optical
•
Output frequency:
≤250 kHz
•
Output signals:
K1, K2, K0 + inverted
•
Output stage:
HTL
TTL/RS422
(As precised on order)
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approvals:
CE, RoHS, UL approval / E256710
10.2
Technical data - mechanical design
•
Size (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft
•
Shaft loading:
≤250 N axial
≤350 N radial
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP 66
•
Operating speed:
≤10000 rpm (mechanical)
•
Operating torque typ.:
2 Ncm
•
Rotor moment of inertia:
320 gcm
2
•
Materials:
Housing: aluminium die-cast alloy and stainless steel
Shaft: stainless steel
•
Operating temperature:
-20…+85 °C
(restricted in potentially explosive environments, see section 2)
•
Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 11 ms
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
•
Connection:
Terminal box
•
Weight approx.:
1.8 kg