10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer POG 90 - Version B10 Benutzerhandbuch

Seite 27: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB154 - 11055767

Baumer_POG90_II_DE-EN (14A2)

24

Technical data

10

10

Technical data

10.1

Technical data - electrical ratings

Voltage supply:

9...30 VDC (HTL)

9...26 VDC (TTL - version R)

5 VDC ±5 % (TTL)

Consumption w/o load:

≤100 mA

Pulses per revolution:

1024...10000 (As precised on order)

Phase shift:

90° ±8°

Scan ratio:

46...56 %

Reference signal:

Zero pulse, width 90°

(width 180° at special version POG 90 ... N)

Sensing method:

Optical

Output frequency:

≤250 kHz

Output signals:

K1, K2, K0 + inverted

Output stage:

HTL

TTL/RS422

(As precised on order)

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, RoHS, UL approval / E256710

10.2

Technical data - mechanical design

Size (flange):

ø115 mm

Shaft type:

ø11 mm solid shaft

Shaft loading:

≤250 N axial

≤350 N radial

Flange:

EURO flange B10

Protection DIN EN 60529:

IP 66

Operating speed:

≤10000 rpm (mechanical)

Operating torque typ.:

2 Ncm

Rotor moment of inertia:

320 gcm

2

Materials:

Housing: aluminium die-cast alloy and stainless steel

Shaft: stainless steel

Operating temperature:

-20+85 °C

(restricted in potentially explosive environments, see section 2)

Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 11 ms

Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

Connection:

Terminal box

Weight approx.:

1.8 kg

Advertising