MB122 - 11055733

Baumer_POG10-NIRO_II_DE-EN (14A2)

18

Technical data

9

9

Technical data

9.1

Technical data - electrical ratings
• Voltage supply:

9...30 VDC* (HTL-P, TTL)

5 VDC ±5 % (TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

1...2500 (As ordered)

• Phase shift:

90° ±20°

• Scan ratio:

40...60 %

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output frequency:

≤120 kHz

≤300 kHz option

• Output signals:

K1, K2, K0 + inverted

• Output stages:

HTL-P (power linedriver)

TTL/RS422

(As ordered)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

CE, UL approval / E256710

9.2

Technical data - mechanical design
• Size (flange):

ø115 mm

• Shaft type:

ø11 mm solid shaft

• Shaft loading:

≤300 N axial; ≤450 N radial

• Flange:

EURO flange B10

• Protection DIN EN 60529:

IP66

• Operating speed:

≤12000 rpm (mechanical)

• Operating torque typ.:

2 Ncm

• Rotor moment of inertia:

340 gcm

2

• Materials:

Housing: stainless steel

Shaft: stainless steel

• Operating temperature:

-40**…+80 °C (Connecting cable fixed)

-20…+80 °C (Connecting cable flexible)

Restricted in potentially explosive environments, see section 2.

• Resistance:

IEC 60068-2-6:2007

Vibration 20 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 200 g, 6 ms

• Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

• Connection:

Connecting cable

• Weight approx.:

4.7 kg

* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution

** Up to -25 °C for versions >3072 pulses per revolution