5. Installation drawing

30

LM

LS >

1.5

x D

T

LH

> L

M+4

0

45

66

DT

d

d

Diameter central borehole
- no special conditioning necessary
- surface quality N8 (Ra 3.2)
- borehole tolerances:
12 -0/+0.25
16 -0/+0.25
20 -0/+0.35
- no screw thread necessary

DT

LM
LH
LS

Bar diameter
Length of measurement position
Depth of central borehole
Measurement position
Ideal depth 1.5 up to 2 times of bar
diameter (steady cross section)

Clamping force per bar

F = A x E x

ε

Force = cross section x E-Modulus x strain

Electrical connections

Current output

Voltage output

Settings

1

2

3 4

5

7

6

1

2

3 4

5

7

6

1

2

3 4

5

7

6

1

2

3 4

5

7

6

P1

S1

P2

LED

1

+ V

S

(18 ... 35 VDC)

1

+ V

S

(18 ... 35 VDC)

2

Test

OUT

2

Test

OUT

3

Reset (bipolar)

3

Reset (bipolar)

4

Reset (bipolar)

4

Reset (bipolar)

5

+I

OUT

(4 ... 20mA)

5

+V

OUT

(-10...10 VDC)

6

-I

OUT

6

-V

OUT

7

GND

7

GND

P1

P2

LED

S1

Setting Test

OUT

Amplifier setting
(Factory made calibration)

LED for Test

OUT

Mounting screw
6mm hex
(Fastening torque 3Nm)

Metal casing with
integrated DMS