Technical data

* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution

9

Technical data

9.1

Technical data - electrical ratings

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

CE, RoHS

9.2

Technical data - electrical ratings (encoder)

• Voltage supply:

9...30 VDC* (HTL-P, TTL - version R)

5 VDC ±5 % (TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

300...2500 (As precised on order)

• Phase shift:

90° ±20°

• Duty cycle:

40...60 %

• Reference signal:

Zero pulse, width 90°

• Output frequency:

≤120 kHz

(≤170 kHz at 500, 512, 1000, 1024, 1200, 2048 and

2500 pulses per revolution)

• Output signals:

K1, K2, K0 + inverted

• Output stage:

HTL-P (power linedriver)

TTL/RS422

(As precised on order)

• Sensing method:

Optical

9.3

Technical data - electrical ratings (centrifugal switch)

• Switching accuracy:

±4 % (Δn = 2 rpm/s)

≤ +20 % (Δn = 1500 rpm/s)

• Switching deviation cw-ccw rotation:

≤3 %

• Switching hysteresis:

~40 % of switching speed

• Switching outputs:

1 output, speed control

• Output switching capacity:

≤6 A / 230 VAC

≤1 A / 125 VDC

• Minimum switching current:

50 mA