8 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer OG 8 Benutzerhandbuch

Seite 21: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB127 - 11055738

Baumer_OG8_II_DE-EN (14A2)

18

Technical data

8

8

Technical data

8.1

Technical data - electrical ratings

•

Voltage supply:

9...26 VDC (HTL, TTL - version R)

5 VDC ± 5 % (TTL)

•

Consumption w/o load:

≤100 mA

•

Pulses per revolution:

1...5000 (As ordered)

•

Phase shift:

90° ±20°

•

Scan ratio:

40...60%

•

Reference signal:

Zero pulse, width 90°

•

Sensing method:

Optical

•

Output frequency:

≤120 kHz

≤300 kHz option

•

Output signals:

K1, K2, K0 + inverted

•

Output stages:

HTL

TTL/RS422

(As ordered)

•

Interference immunity:

EN 61000-6-2:2005

•

Emitted interference:

EN 61000-6-3:2007/A1:2011

•

Approvals:

CE, UL approval / E256710

8.2

Technical data - mechanical design

•

Size (flange):

ø85 mm

•

Shaft type:

ø11 mm solid shaft

•

Shaft loading:

≤50 N axial

≤60 N radial

•

Flange:

EURO flange B10

•

Protection DIN EN 60529:

IP54

•

Operating speed:

≤12000 rpm (mechanical)

•

Operating torque typ.:

1 Ncm

•

Rotor moment of inertia:

18 gcm

2

•

Materials:

Housing: aluminium die-cast

Shaft: stainless steel

•

Operating temperature:

-30…+85 °C

-25…+85 °C (>3072 pulses per revolution)

•

Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 6 ms

•

Connection:

Connecting terminal

•

Weight approx.:

700 g