Technical data

8

8

Technical data

8.1

Technical data - electrical ratings

Voltage supply:

9...26 VDC (HTL, TTL - version R)

5 VDC ± 5 % (TTL)

Consumption w/o load:

≤100 mA

Pulses per revolution:

1...5000 (As ordered)

Phase shift:

90° ±20°

Scan ratio:

40...60%

Reference signal:

Zero pulse, width 90°

Sensing method:

Optical

Output frequency:

≤120 kHz

≤300 kHz option

Output signals:

K1, K2, K0 + inverted

Output stages:

HTL

TTL/RS422

(As ordered)

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, UL approval / E256710

8.2

Technical data - mechanical design

Size (flange):

ø85 mm

Shaft type:

ø11 mm solid shaft

Shaft loading:

≤50 N axial

≤60 N radial

Flange:

EURO flange B10

Protection DIN EN 60529:

IP54

Operating speed:

≤12000 rpm (mechanical)

Operating torque typ.:

1 Ncm

Rotor moment of inertia:

18 gcm

2

Materials:

Housing: aluminium die-cast

Shaft: stainless steel

Operating temperature:

-30+85 °C

-25…+85 °C (>3072 pulses per revolution)

Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 6 ms

Connection:

Connecting terminal

Weight approx.:

700 g