8 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer OG 8 Benutzerhandbuch
Seite 21: Technical data, Technical data - electrical ratings, Technical data - mechanical design
MB127 - 11055738
Baumer_OG8_II_DE-EN (14A2)
18
Technical data
8
8
Technical data
8.1
Technical data - electrical ratings
•
Voltage supply:
9...26 VDC (HTL, TTL - version R)
5 VDC ± 5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
1...5000 (As ordered)
•
Phase shift:
90° ±20°
•
Scan ratio:
40...60%
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz
≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted
•
Output stages:
HTL
TTL/RS422
(As ordered)
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approvals:
CE, UL approval / E256710
8.2
Technical data - mechanical design
•
Size (flange):
ø85 mm
•
Shaft type:
ø11 mm solid shaft
•
Shaft loading:
≤50 N axial
≤60 N radial
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP54
•
Operating speed:
≤12000 rpm (mechanical)
•
Operating torque typ.:
1 Ncm
•
Rotor moment of inertia:
18 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-30…+85 °C
-25…+85 °C (>3072 pulses per revolution)
•
Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 6 ms
•
Connection:
Connecting terminal
•
Weight approx.:
700 g