Danger

Warnings of possible danger.

General instructions

Information on appropriate product handling.

General remarks

Additional information

The installation instruction is supplementary to further

documentation (e.g. catalog, data sheet, manual).

It is imperative to read the manual carefully prior to star-

ting the device.

Appropriate use

- The encoder is a precision measuring device. It is ex-

plicitly designed for registration of angular positions

and revolutions as well as evaluation and supply of

measuring values as electric output signals for the sub-

sequently connected device. The encoder must not be

used for any other purpose.

Start up

- Installation and assembly of the encoder only by electri-

cally skilled and qualified personnel.

- Consider also the operation manual of the machine

manufacturer.

Safety instructions

- All electrical connections are to be revised prior to star-

ting the system.

- Incorrect assembly and electrical connections or any

other inappropriate work at encoder and system may

lead to malfunction or failure of the encoder.

- Any risk of personal injury, damage of the system or

company equipment due to failure or malfunction of the

encoder has to be eliminated by corresponding safety

measures.

- Do not operate encoder beyond the limit values stated

in the data sheet.

Any disregard may lead to malfunctions, material damage

and personal injury.

G0A2H, G0L2H, G0M2H
GBA2H, GBM2H
Absolute encoder – SSI

9-16

Assembly Instructions

GB

The braided shield has to be connected to cable gland

or plug. Grounding (PE) on both sides is recommended.

Ground the case by the mechanical assembly, if latter

is electrically isolated a second connection has to be

provided. Ground cable screen by the subsequently

connected devices. In case of ground loop problems at

least grounding on one side is imperative.

- Any outputs not used must not be connected. Unused

cable cores have to be isolated. Max. allowed bending

radius of cable: 90 mm

Any disregard may lead to malfunctions, material damage

and personal injury.

Connection – M23-Connector

Whilst not connected, the plug is always to be sealed by

the plastic cover provided by the manufacturer upon de-

livery. Appropriate mating connectors available as spare

part or with different cable length, please refer to acces-

sories. In case of customer-specific length use only scree-

ned cable and connectors corresponding to EMC stan-

dards. Consider the wiring instructions of the respective

supplier.

- Press mating connector softly onto the plug.

- Turn mating connector until the code-mark is interlo-

cking the corresponding space provided by plug.

- Insert bushing completely.

- Tighten the nut as far as possible.

Terminal assignment
Connector Core colour Assignment
Pin 1

brown

UB

Pin 2

black

GND

Pin 3

blue

Clock+

Pin 4

beige

Data+

Pin 5

green

Zero setting

Pin 6

yellow

Data-

Pin 7

violet

Clock-

Pin 8

brown/yellow DATAVALID

Pin 9

pink

UP/DOWN

Pin 10

black/yellow DATAVALID MT

(only G0L2H, G0M2H, GBM2H)

Pin 11 / 12 –

All movable adjusting elements need tolerance in both

axial and radial direction in order to equalize shifts by tem-

perature and of mechanical nature. Tighten both fixing and

clamping ring screws firmly.

Starting torque
Spring coupling mounting max. 1.2 Nm
Clamping ring mounting M3 max. 1.2 Nm

Electrical installation

- Do not modify encoder in any electrical way and carry

out any wiring work under power supply.

- Any electrical connection and plugging-on whilst under

power supply is not permitted.

- A separate encoder supply has to be provided with con-

sumers with high interference emission.

- Installation of the whole system has to be according

to EMC standards. Installation environment as well as

wiring have an impact on the encoder’s EMC. Encoder

and supplying lines are to be in separated locations or

remote from lines with high interference emission (fre-

quency transformers, protections, etc.).

- Encoder case and supply cable have to be completely

screened.

- Ground (PE) encoder by using screened cables.

Terminal assignment incremental tracks | sine/cosine
Connector Core colour Assignment

incremental Sine/cosine

Pin 1

brown

UB

UB

Pin 2

white

GND

GND

Pin 3

blue

Clock+

Clock+

Pin 4

green

Data+

Data+

Pin 5

grey

Zero setting

Zero setting

Pin 6

yellow

Data-

Data-

Pin 7

red

Clock-

Clock-

Pin 8

red/blue

Track B inv.

Cosine

Pin 9

pink

UP/DOWN

UP/DOWN

Pin 10

violet

Track A inv.

Sine

Pin 11

black

Track A

Sine

Pin 12

grey/pink

Track B

Cosine

An optimized connection between encoder case and the

braided shield of the connection cable is only achieved by

the braided shield being placed generously onto the con-

nector and the nut being secured firmly. Please use cores

twisted in pairs (for example clock+/clock-) for extension

cables of more than 10 m length.

1

2

3

4

5

6

7

8

9

10

12

11

11

4.

5

10.

5

53.5

63.75

20.5

95.75

20.5

30

7

0.

3

133.5

Spring coupling

Disposal

Encoder components are to be disposed of according to

the regulations prevailing in the respective country.

Transport and storing

- In original packing only.

- Do not drop or expose encoder to major shocks.

Assembly

- Open clamping ring completely before mounting the

encoder.

- Avoid punches or shocks on case and shaft.

- Avoid case distortion.

- Do not open or modify encoder in any mechanical way.

- The spring arm of the spring coupling has to be free

movable.

Hollow shaft, bearing, glass disc or electronic

components might be damaged and a secure

operation is no longer guaranteed.

Hollow shaft mounting

Mounting with clamping ring

Plug encoder completely onto drive shaft (ISO-fit f7) and

tighten clamping ring firmly.

The drive shaft must penetrate the encoder’s hollow shaft

to a depth of at least 35 mm.

Mechanical assembly

Slide encoder onto the drive shaft and insert torque pin

into the adjusting element provided by customer or

insert pin into the mounted adusting part (with rubber

spring element) provided by customer.

Spring coupling

Fasten spring coupling at the fixing holes provided on housing by means of screws.

Slide encoder onto the drive shaft and fasten spring coupling at the surface provided

with screws.

drive

shaft

clamping ring

7

0.3

6.6

30

40.

5

7.

5

53.

5

M3

(1.2 Nm)

35

30
10

15.1

19.1

49.

3

7.

6

7.6

M3 (1.2 Nm)

SW2.5

20

°

20

73

81

M3x6 (1.2 Nm)

12 ±0.5

M3 (1.2 Nm)

SW2.5

20

77
68

20

°

M3 (1.2 Nm)

SW2.5

12

M4x6 (1.9 Nm)









¡IJ

torque pin

40.5

20.5

50 38

5

±0.5

1.25

torque pin

adjustment

piece

rubber spring

element

adjustment piece with

torque pin 9.5 mm

4

2.5

22

30°

67°

25°

R37.25

R43.5

73

80

SW2.5

62

20°

51

M3x6 DIN912

6

Dimensions - clamping ring on flange



















 

¡IJ

























¡+ ¡+

ƒ

0[ [













¡+ ¡+

ƒ

0[ [













 







¡

IJ



¡











Dimensions - clamping ring on housing

Advertising