8 technical data, 1 technical data - electrical ratings, 3 technical data - electrical ratings (sinewave) – Baumer MHGP 100 Benutzerhandbuch

Seite 26: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (square-wave), Technical data - electrical ratings (sinewave)

Advertising
background image

23

Baumer_MHGP100-T1_II_DE-EN (14A3)

MB210T1 - 11121634

8

Technical data

8

Technical data

8.1

Technical data - electrical ratings

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

CE, RoHS

8.2

Technical data - electrical ratings (square-wave)

• Voltage supply (Signals):

RN...C: 4,5...30 VDC (TTL/RS422)

TN...C: 5 VDC ±5 %

(TTL/RS422)

HN...C: 10...30 VDC

(HTL)

UN...C: 5...30 VDC

(TTL/HTL)*

• Consumption w/o load:

≤160 mA

• Pulses per revolution:

64...131072 (As ordered)

• Phase shift:

90° ±10°

• Scan ratio:

40...60 %

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Magnetic

• Output frequency:

≤2 MHz

• Output signals:

A+, B+, R+, A-, B-, R-

• Output stages:

HTL

TTL/RS422

(As ordered)

8.3

Technical data - electrical ratings (sinewave)

• Voltage supply (Signals):

PN...C: 4,5...30 VDC (SinCos)

• Consumption w/o load:

≤160 mA

• Sinewave cycles per turn:

64...8192 (As ordered)

• Phase shift:

90° ±5

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Magnetic

• Output signals:

A+, B+, R+, A-, B-, R-

• Output stage:

SinCos 1 Vpp

• Difference of SinCos amplitude:

≤20 mV

• Harmonics typ.:

-40 dB

• DC offset:

≤20 mV

• Bandwidth:

400 kHz (-3 dB)

* At +UB = 5 VDC: TTL/RS422; At +UB = 10...30 VDC: HTL

Advertising