Error 2 : Line (Position) not available or separation line
Error 3 : Parameter error (Non-admissible value in protocol).
This means, for example, that the preselection value does not
only consist of digits, but also of other non-admissible
characters, or that a value has been indicated that is not
within an admissible range.
Error 4 : This error message occurs if the PC requests the counter NE215
to print in the programming mode, if the printout of any line
except the lines 01-03 and 05 is to be initiated, or if the PC
does not send Date/Time or sends them in a wrong format. The
counter will not allow the value to be sent to the printer and
responds with an error mistake to the PC.
Example for a returned error message:
Address=35, Line=01, Error number=4
<STX>3501D<CAN>4<ETX><CR>
8. List of the control characters in use
Control character
Hex
Decimal
<STX> 02
02
<ETX> 03
03
<ACK> 06
06
<LF> 0A
10
<CR> 0D
13
<DC1> 11
17
<CAN> 18
24
<DEL> 7F
127