Baumer NE215 Benutzerhandbuch
Seite 20
Advertising

NE215
20 www.baumer.com
Line 38
Time basis for tachometer
function
0 1 second
1 2 Seconds
2 3 Seconds
3 6 Seconds
4 10 Seconds
5 20 Seconds
6 30 Seconds
7 60 Seconds
Line 39
Not applicable
Line 40
Function Operating time meter
0 Operating time meter is running
1 Operating time ON / OFF
Line 41
Code setting
0000 Code not active
:
9999
Line 43
Baud rate
0 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 44
Parity
0 Even Parity
1 Odd Parity
2 No Parity
Line 45
Device address
00 Minimum value
:
99 Maximum value
Line 46
Stop Bit
0 1 Stop Bit
1 2 Stop Bit
Advertising