10. Programming plan
Lines in italics = Factory setting
Zl 11-18 Status for Line 1-8
0 Parameter can be changed
1 Clear and/or input disabled
2 Parameter is skipped
Line 21
Operating mode Principal count
system
0 Progressive preselections
1 P1-Trailing preselection
Line 22
Not applicable
Line 23
Scaling factor Batch counter
00 Minimum value
1 Default value
99 Maximum value
Line 24
Not applicable
Line 25
Not applicable
Line 26
Frequency Batch counter Counting
input
0 10 kHz
1 25 Hz
2 15 Hz
Line 27
Not applicable
Line 28
Not applicable
Line 29
Not applicable
Line 30
Reset Batch counter
0 autom. reset and external stat.
1 autom. reset and external diff.
2 external static
3 external differential
Zl 31-33 Output time P1, P2, P3
00.00 Maintained contact (LAtcH
displayed)
0.25 Default value
99.99 Maximum value
Line 34
Take-over of preselections
P1,P2,B
0 in case of reset
1 after input
Line 35
Address for function key
0 Function key not connected
:
8 Maximum value
Line 36
Function of Batch counter
0 external
1 internal
2 Tachometer
Line 37
Impulses per unit at tachometer
00.00 Minimum value
1.00 Default value
9999.99 Maximum value